Rockwell Automation SP200 AC Drive, 1 2 Channel Analog, Preset Speed User Manual
Page 54

A-2
Installing and Operating the SP200 AC Drive
Operating Performance
•
Input frequency resolution: 0.4% analog; 0.1 Hz digital
•
Output frequency resolution: 0.1%
•
Output voltage regulation: 3%
•
Power dip control ride through time: 100 msec minimum
Drive Power Loss
•
Typical Full load power loss:
Ambient Conditions
•
Operating temperature: 0
°
C to 50
°
C (32
°
F to 122
°
F)
•
Storage temperature: -40
°
C to 85
°
C (-40
°
F to 185
°
F)
•
Humidity: 0 to 95% non-condensing
•
Elevation: 1000 meters (3300 ft) maximum without derating. For every 91.4
meters (300 ft) above 1000 meters, derate the current by 1%. Above 3000 meters,
(10,000 ft), consult your Reliance Electric Sales Office.
Dimensions
•
Height: 139.8 mm (5.5 in)
•
Width: 72.0 mm (2.835 in)
•
Depth: 138.8 mm (5.47 in)
Standards and Approvals
•
UL508C
•
CSA22.2
•
EN50178, EN60204-1 for Low Voltage Directive
•
EN50081-1, EN50082-2, parts of EN61800-3 for EMC
Input Voltage
Unit HP
Typical Power Dissipation (W)
2 kHz
4 kHz
6 kHz
8 kHz
100 -120, 1-phase
0.5
1.0
1.5
25
45
70
27
48
73
28
50
77
30
52
80
200 - 240, 1-phase
0.5
1.0
1.5
2.0
25
45
70
75
27
48
73
80
28
50
77
85
30
52
80
90
200 - 240, 3-phase
0.5
1.0
2.0
25
40
70
27
43
75
28
45
80
30
47
85
380 - 460, 3-phase
0.5
1.0
2.0
25
30
50
30
37
60
35
44
72
40
50
85