Solar Turbine Addendum

Step 3. Tighten the DC input power terminals to the proper torque, as listed in

table 4.3.

!

ATTENTION: On the 5 HP Solar Turbine drive, the positive DC input must be connected to the
(+) terminal. The negative DC input must be connected to the (–) terminal. These terminals
cannot be interchanged. Failure to observe this precaution could result in damage to, or
destruction of, the equipment.

Figure 4.2 – DC Input Terminals

U/T1

W/T3

V/T2

Motor Leads

DC Negative

Input

5 HP Drive

1 HP Drive

W/T3

V/T2

U/T1

10V

10 COM

Motor Leads

DC Bus

Volts

B1

B2

DC Inputs

DC Positive

Input

(+)

(-)

Table 4.3 – Terminal Tightening Torques

Drive

Terminals

Maximum Tightening Torque

1 HP

All

1.08 Newton-meters (9.5 in-lbs)

5 HP

All

13.5 Newton-meters (10 ft-lbs)