WebPak 3000 DC Drive Application Workbook, Version 1.1

3.1

The Speed Loop Reference

Refer to figure A.4 in Appendix A of the software manual (D2-3444) as you set up the
speed loop reference.

The setup of the speed reference depends on the control source selected. The control
source selections are:

KEYPAD

- The drive uses the reference from the OIM.

Important: If you select

KEYPAD

as the control source, the drive can be used to

regulate speed only.

TERMBLK

- The drive uses the reference from the Regulator board terminal strip.

SERIAL

- The drive uses the reference from a serial device (for example, a PC running

WebPakCS software).

NETWORK

- The drive uses the reference from the network.

þ

To select the control source:

▲

If you are using the WebPakCS software to program the drive, you configured
the control source during the initialization process by setting

CONTROL

SOURCE

SELECT

(P.000).

▲

If you are using the OIM to program the drive, select the control source
using

þ

If the

CONTROL

SOURCE

(P.000) =

TERMBLK

:

▲

Specify the line speed signal type in

LINE

SPEED

REF

SELECT

(P.103). The

choices are:

ANALOG

FREQUENCY

IN

- The frequency input is typically used to daisy-chain

multiple drives.

þ

If

LINE

SPEED

REF

SELECT

(P.103) =

ANALOG

:

▲

Verify that an analog line speed reference is connected to
terminals 19(+) and 20(-) on the Regulator board.

▲

Set

LINE

SPEED

SIG

TYPE

(P.100).

Important: Jumpers J10 and J12 must be set for the type of line speed signal

selected. See the drive hardware manual (D2-3443) for instructions.

▲

Set

LINE

SPEED

GAIN

ADJ

(P.101) to adjust the gain for the line

speed input.

Range:

KEYPAD

,

TERMBLK

,

SERIAL

,

NETWORK

P.000 =

Range:

ANALOG

,

FREQUENCY

IN

P.103 =

Range: 0 to 10V, +/-10V, 4 to 20mA, 10 to 50mA

P.100 =

Range: 0.750 to 2.250

P.101 =