5.4
The Field Regulator
The field current regulator operates closed loop with a
PI
amplifier block.
FIELD
DELTA
(P.588) is the output of the
PI
block and sets the firing angle of the field phase firing
logic which, in turn, sets the voltage output level of the field power bridge.
þ
To modify the lead frequency and gain of the
FIELD
AUTO
WEAKEN
PI
block
(recommended for stable operation of the field current regulator
PI
block):
▲
Set
FIELD
PI
PROP
GAIN
(P.514) to tune for stable operation of the spillover
regulator
PI
block.
▲
Set
FIELD
PI
LEAD
FREQ
(P.515) to tune for stable operation of the spillover
regulator
PI
block.
Range: 0 to 120% of P.009
P.518 =
%
Range: 0.00 to 56.54
RAD
/
S
P.520 =
RAD
/
S
Range: 0.01 to 128.00
P.519 =
Range: 0.10 to 128.00
P.514 =
Range: 0 to 282.70
RAD
/
S
P.515 =
RAD
/
S