Drive Configuration
3-5
3.10 NETWORK KIT (P.796)
NETWORK
KIT
(P.796) indicates whether the network option board is operating correctly
in the drive.
Range:
PRESENT
(1),
NOT
PRESENT
(2),
FAILED
DIAGS
(3)
Type: Read-only (output)
3.11 NETW IN REG 1 (P.905)
NETW
IN
REG
1 (P.905) indicates the value being written by the network master into file
address N11:10 in the network option board’s dual-port memory.
Range: -4095 to 4095
Type: Read-only (output)
3.12 NETW IN REG 2 (P.906)
NETW
IN
REG
2 (P.906) indicates the value being written by the network master into file
address N11:11 in the network option board’s dual-port memory.
Range: -4095 to 4095
Type: Read-only (output)
3.13 NETW IN REG 3 (P.907)
NETW
IN
REG
3 (P.907) indicates the value being written by the network master into file
address N11:12 in the network option board’s dual-port memory.
Range: -4095 to 4095
Type: Read-only (output)