Rockwell Automation Flex/WebPak 3000 DC Drive ControlNet, Network Communication Board, 915FK2101 User Manual
Page 84

8-16
ControlNet Network Communication Option Board For Use With FlexPak 3000 and WebPak 3000 DC Drives
N10:234
LEVEL
DETECT
2
B
SEL
P.611
Config
0 =
LEVEL
REGISTER
1
1 =
LEVEL
REGISTER
2
2 =
CML
SPEED
REFERENCE
3 =
CML
REFERENCE
4 =
CML
FEEDBACK
5 =
CML
ERROR
6 =
SPD
SOURCE
SELECT
OUT
7 =
SPEED
RAMP
OUTPUT
8 =
SPD
LOOP
REFERENCE
9 =
SPD
LOOP
FEEDBACK
10 =
SPD
LOOP
OUTPUT
11 =
TRIM
OUTPUT
12 =
NORM
FIELD
REF
13 =
FIELD
DELTA
14 =
FIELD
FEEDBACK
15 =
FIELD
REFERENCE
16 =
TEN
LOOP
ERROR
17 =
TENSION
DEMAND
18 =
TEN
/
DANCER
FDBK
SCALED
19 =
POS
LOOP
ERROR
20 =
DANCER
LOADING
21 =
OCL
OUTPUT
22 =
OCL
PARALLEL
OUT
23 =
NORM
ROLL
DIAMETER
24 =
LOSSES
COMPENSATION
25 =
INERTIA
COMPENSATION
26 =
INSTANTANEOUS
INERTIA
27 =
TAPER
PERCENT
28 =
CURRENT
MEM
COMMAND
29 =
STALL
TENSION
COMMAND
30 =
NETW
IN
REG
1
31 =
NETW
IN
REG
2
N10:235
CURRENT
/
SPEED
SWITCH
P.811
Config
0 =
DISABLE
, 1 =
ENABLE
N10:236
NETW
CONNECT
TYPE
P.910
Config
0 =
BASIC
, 1 =
FULL
N10:237
AMX
NETW
REF
SELECT
P.911
Config
0 =
DIRECT
N
=
BROADCAST
N
, where
N
= 1 to 8
N10:238
|
N10:273
Reserved
---
---
Reserved (future parameter expansion)
Table 8.1 – File N10:x (Drive Read/Write Parameters) for WebPak 3000 Drives (Continued)
File
Address
Parameter Name
Parameter
Number
Type
Scale