Sensor docking station, Analog sensor wiring – Bully Dog 4038x Sensor Docking Station User Manual

Page 28

Advertising
background image

27

Sensor Docking Station

Analog Sensor Wiring

There are two openings on each analog sensor docking port.

The AN+ dock supports a 0-5 volt signal wire from the sensor.

The AN- dock is an optional ground connection; however, it

is recommended that you use the chassis ground if a sensor

requires a ground connection. (This should be the same

chassis ground used for the power harness.)
The diagram below illustrates the wiring configuration for a

three-wire analog sensor.

1. Power in to the sensor. Key-on power only (5-12 volts).

2. Signal out from the sensor (0-5 volts).

3. Ground connection. (This must be connected to the same ground

location as the Sensor Docking Station chassis ground wire.)

Advertising