Calculated Industries 4090 User Manual
Page 55

54 — ITI S
HEET
M
ETAL
/HVAC P
RO
B) Solve Using:
a. Actual Length “x”: 52-5/8 Inches
b. Offset “y”: 25-3/16 Inches
c. End “a”: 34 Inches
KEYSTROKE
DISPLAY
1. Enter actual Length as “x”:
o o
0.
5 2 i 5 / 8 R
X 52-5/8
INCH
2. Enter offset Length as “y”:
2 5 i 3 / 1 6 r
Y 25-3/16
INCH
3. Enter Height of “end A” as “a”:
3 4 i Ç 4
A
34
INCH
4. Calculate Centerline Radius, Wrapper Length, Heel Radius,
Throat Radius and Theta:
Ç (
RAD 33-13/16
INCH
(
WL 60-5/16
INCH
(
HEEL 50-13/16
INCH
(
THRT 16-13/16
INCH
(
THET 25.57682°
“WL”, or the Wrapper, corresponds to the side of the fitting associat-
ed with the offset dimension used for the calculation. The longest
Wrapper corresponds to the side with the largest offset (y).
Caution: When working with a “Change Transitional OGEE
Offset” (Wrapper size transitions from one end to other) the length
of a cheek having a slant length must be adjusted to include
that slant length prior to the calculations above taking place.