Stairs — Given Only the Run

You’re building a stairway with a total Run of 20 Feet. Your desired
Riser height is 7-1/2 Inches and desired Tread width is ten Inches
(default, or preset values). The desired headroom is 6 Feet 8 Inches
and floor thickness 10 Inches (defaults). Find all stair values, then
calculate the Rise.

KEYSTROKE

DISPLAY

1. Enter Run:

o o

0.

2 0 f R

X 20

FEET

0

INCH

2. Find Riser height, number of Risers, Riser Overage/Underage,
Tread width, number of Treads, Tread Overage/Underage, stairwell
opening, Stringer length and Angle of Incline. As a final step, calcu-
late the Rise:

s

R-HT 7-1/2

INCH

s

RSRS 25.

s

R+/– 0

INCH

s

T-WD 10

INCH

s

TRDS 24.

s

T+/– 0

INCH

s

OPEN 10

FEET

0

INCH

s

STRG 25

FEET

0

INCH

s

INCL 36.8699°

s

RUN (

X

)

20

FEET

0

INCH

s

RISE 15

FEET

7-1/2

INCH

STORED