Stairs — Given Only Floor-to-Floor Rise

You’re building a stairway with a total Rise of 9 Feet 11 Inches. Your
desired Riser height is 7-1/2 Inches and desired Tread width is 10
Inches. The desired Headroom is 6 Feet 8 Inches and Floor
Thickness 10 Inches*. Find all stair values, then calculate the Run.

*Note: Headroom and Floor Thickness are required to calculate the height of the stair-
well opening.

KEYSTROKE

DISPLAY

1. Enter known Rise:

o o

0.

9 f 1 1 i r

Y 9

FEET

11

INCH

2. Recall (default) stored “desired” stair Riser height:

® s

R-HT

7-1/2

INCH

3. Find Riser height, number of Risers, Riser Overage/Underage,
Tread width, number of Treads, Tread Overage/Underage, length of
stairwell opening, Stringer length and Angle of Incline. As a final
step, calculate the Run:

s

R-HT 7-7/16

INCH

s

RSRS 16.

s

R+/– 0

INCH

s

T-WD 10

INCH

s

TRDS 15.

s

T+/– 0

INCH

s

OPEN 10

FEET

1

INCH

s

STRG 15

FEET

6-15/16

INCH

s

INCL 36.64003°

s

RUN 12

FEET

6

INCH

s*

RISE (

Y

)

9

FEET

11

INCH

*Continuous presses of

s will also recall stored desired Riser height, Tread,

Headroom and Floor Thickness values.

STORED