Calculated Industries 4090 User Manual

Page 88

Advertising
background image

U

SER

S

G

UIDE

— 87

Common Rafter Length

If a roof has a 7/12 Pitch and a Span of 14 Feet 4 Inches, what is
the Point-to-Point length of the Common rafter (excluding the over-
hang or ridge adjustment)? What are the Plumb and Level cuts?

KEYSTROKE

DISPLAY

1. Find Diagonal or Point-to-Point length of the Common rafter:

o o

0.

7 i p

PTCH 7

INCH

1 4 f 4 i ÷ 2 =

7

FEET

2

INCH

R

X 7

FEET

2

INCH

d

R 8

FEET

3-9/16

INCH

2. Find Plumb and Level cuts:

d

PLMB 30.25644°

d

LEVL 59.74356°

Common Rafter Length — Pitch Unknown

Find the Common rafter length for a roof with a Rise of 6 Feet 11-1/2
Inches and a Run of 14 Feet 6 Inches. Solve for the Pitch in
Degrees and in Inches.

KEYSTROKE

DISPLAY

Find Diagonal and Pitch:

o o

0.

6 f 1 1 i 1 / 2 r

Y 6

FEET

11-1/2

INCH

1 4 f 6 i R

X 14

FEET

6

INCH

d

R 16

FEET

1

INCH

p

PTCH 5-3/4

INCH

p

/_ Ш 25.63565°