Communication and Environmental

Hardware (RS-485)

Interface: 2-wire half-duplex RS-485
Baud rates: 9.6k, 19.2k (default), or 38.4k
Data format: 8 data bits, no parity, 1 stop bit

Protocol

Modbus RTU

Shock and Vibration

IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz

Rating

DX80 Models:IEC IP67; NEMA 6; (See UL section be-
low for any applicable UL specifications)
DX80...C Models: IEC IP20; NEMA 1

Operating Environment

Temperature: −40 to +85 °C (Electronics); −20 to +80
°C (LCD)
Humidity: 95% max. relative (non-condensing)
Radiated Immunity: 10 V/m, 80-2700 MHz
(EN61000-6-2)

Refer to the

SureCross DX80 Wireless I/O Network Product Man-

ual

(p/n 132607) for installation and waterproofing instructions. Op-

erating the devices at the maximum operating conditions for exten-
ded periods can shorten the life of the device.

Certifications

DX8x...C (External Wiring Terminal Models)

CSA: Class I, Division 2, Groups A, B, C, D

(Ex/A Ex nA II T4); Certificate: 1921239

LCIE/ATEX: Zone 2 (II 3G / Ex nA IIC); Certifi-

cate: LCIE 10 ATEX 1012 X

UL Listing

Maximum ambient temperature: 70 °C
Mounting instructions: See document 132607
Power rating: 10 to 30V dc, UL Class 2
Enclosure environmental rating: UL Type 1

Included with Model

The following items ship with the DX80 radios.

• BWA-HW-002: DX80 Access Hardware Kit, containing four PG-7 plastic threaded plugs, four PG-7 nylon gland fittings, four PG-7 hex

nuts, one 1/2-inch NPT plug, and one 1/2-inch nylon gland fitting. (Not included with IP20 DX80...C models)

• BWA-HW-001: Mounting Hardware Kit, containing four M5-0.8 x 25mm SS screws, four M5-0.8 x 16mm SS screws, four M5-0.8mm

SS hex nuts, and four #8-32 x 3/4" SS bolts

• BWA-HW-003: PTFE tape
• BWA-9O2-C (900 MHz) or BWA-2O2-C (2.4 GHz): Antenna, 2 dBd Omni, Rubber Swivel RP-SMA Male. (Not included with Internal

antenna models)

• Quick Start Guide (128185 for DX80 Gateways or 152653 for MultiHop models)
• MQDC1-506: 5-Euro (single ended) straight cable, 2m (Not included with FlexPower devices)
• BWA-HW-011: IP20 Screw Terminal Headers (2 pack) (Included only with the IP20 DX80...C models)

Warnings

Antenna Installations. Install and properly ground a qualified surge suppressor when installing a remote antenna system. Remote antenna
configurations installed without surge suppressors invalidate the manufacturer's warranty. Keep the ground wire as short as possible and make all
ground connections to a single-point ground system to ensure no ground loops are created. No surge suppressor can absorb all lightning strikes; do
not touch the SureCross® device or any equipment connected to the SureCross device during a thunderstorm.

Exporting SureCross Radios. It is our intent to fully comply with all national and regional regulations regarding radio frequency emissions. Custom-
ers who want to re-export this product to a country other than that to which it was sold must ensure the device is approved in the destina-
tion country.
A list of approved countries appears in the Radio Certifications section of the product manual. The SureCross wireless products were
certified for use in these countries using the antenna that ships with the product. When using other antennas, verify you are not exceeding the transmit
power levels allowed by local governing agencies. Consult with Banner Engineering Corp. if the destination country is not on this list.

SureCross DX80 Gateway for M-GAGEs

8

www.bannerengineering.com - tel: 763-544-3164

P/N 134303 Rev. H

Advertising