Specifications, Guard opening calculation (before switching) – Banner SI-HG63 Hinge Style Switches User Manual

Page 10

Advertising
background image

Specifications

Contact Rating

3 A @ 230V ac max., 1.0 A @ 24V dc max.
2.5 kV max. transient tolerance
European Rating:
U

i

= 250V

U

e

= 230V AC, 24V DC

Ithe = 4A
Utilization categories: AC-15: U

e

/I

e

230 V / 3A;

DC-13: U

e

/I

e

24 V / 1 A (IEC/EN 90497-5-1)

Electrical Protection Class

II, protective insulation

Contact Function

Slow make and break contacts, 2 N.C., 1 N.O.

Switching Frequency

Max. 300 operations/h (5 operations per minute)

Switching Angle

N.C. Contact: ± 3°, Positive-opening ± 6° (wear can
cause increase by 2°)
N.O. Contact: ± 9°
Tolerance for all angles: 1.5°

Mechanical Load

SI-HG63..: F

R1

= 1800 N max., F

R2

= 750 N max., F

A

=

1800 N max.
SI-HGZ63..: F

R1

= 1200 N max., F

R2

= 500 N max., F

A

= 1200 N max.
For direction of loaded forces, see Operating Range

Mechanical Life

1 million operations
Excessive loading (force) and/or vibration, as well as
improper installation, can reduce the service life.

B10d

2 x 10

6

cycles

Short Circuit Protection

4 amp Slow Blow. Recommended external fusing or
overload protection.

Operating Range

0 to 270°

Wire Connections

6-pin Micro-style quick-disconnect fitting (M12 Dual-
Key-Way). Cordsets are ordered separately.

Construction

SI-HG63..: Hinge: Cast Stainless Steel (X22CrNi 17);
Switch: PBT
SI-HGZ63..: Hinge: zinc die cast (nickel finish); Switch:
PBT

Environmental Rating

IP67 acc. to IEC/EN 60529

Operating Conditions

–25 °C to +70 °C (−13 °F to +158 °F)
(connecting cable permanently mounted; no freezing
over / no condensation)

Mounting

4 x M6 screws DIN EN ISO 7984 (on flat and stiff sur-
face)

Weight

SI-HG63..: approximately 0.45 kg
SI-HG63A: approximately 0.27 kg
SI-HGZ63..: approximately 0.4 kg
SI-HGZ63A: approximately 0.22 kg

Application Notes

To avoid excessive radial stress in applications con-
taining large doors, the hinge switch must be mounted
either in pairs of two, or in conjunction with a blank
hinge.

Applicable Standards

VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1

EU-Conformity

According to directive 2006/42/EG
According to directive 2006/95/EC

Approvals

C

CSA

US

B300

Certifications

Guard Opening Calculation (before switching)

The size opening between the machine frame and the guard can be estimated based on the table provided. This can assist in determin-
ing safety distance as described by ANSI B11.19 or ISO 13857.

Hinge Wing Safety Interlock Switches

10

www.bannerengineering.com - tel: 763-544-3164

Datasheet

129465_web Rev.

D

Advertising
This manual is related to the following products: