Running inspections running inspections – Banner PresencePLUS BCR 1.3 Series User Manual
Page 10

10
P/N 118000 rev. D
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
running
inspections
running
inspections
Viewing Results
Display Options
Select an inspection to run, and view the results of the inspection.
To select an inspection, (in the Select tab) enable Software Override and
select the inspection file from the list of stored inspections.
Alternate method: Use Hardware Input to select an inspection via Product
Change and Product Select lines.
TIPS
When using the
Hardware input,
pulse the Product
Change and
Product Select
inputs to initiate
an inspection
change. See the
User’s Manual in
the Help menu
for complete
information.
.
Next Pass
Display only the next passing inspection.
Next Fail
Display only the next failing inspection.
Next RT
Display the next remote teach.
Next RT Fail
Display the next unsuccessful remote teach.
Next
Continuously display inspections.
None
Don’t display any inspections.
Click + to
expand and
– to contract
category
Click on
tool name
to show
the ROI
Passing
Tool
Failing
Tool
To begin inspecting, click the Start button in the Run screen.
This screen automatically configures the parameters chosen in the
Tools screen.
a. Choose the sample size
b. Click Start
c. Trigger the controller with the external trigger device
d. Click Stop
e. Click Next to proceed to Run
Before entering Run, save the inspection file to one of the 12 memory
locations on the Sensor.