PROBLEM

PROBABLE CAUSE

SOLUTION

Dereel unit won’t run.

Dereel switch on manual.

Turn collar of dereel switch to
auto.

Dereel unit runs on.

Wire not properly routed along
supply shoot.

Route wire from top of spool to
supply chute and up to wire
cutting unit. Make sure wire is
routed to pass in front of prox
switch located on the supply
chute.

Wire tangled with scrap paper.

Adjust supply chute height to
prevent wire from tangling with
scrap paper.

Check height of spool prox
switch.

The face of the prox switch
should be flush or slightly
protruding on the supply chute.

Faulty spool prox switch.

Replace prox switch.

Wire stretching or
sagging on the bottom
of spool.

Supply chute.

Adjust supply chute height to
accommodate wire size.

Wire not traveling
smoothly through wire
feed and cutting unit.

Wire guides too tight.

Check width of feed wheel
guide.
Check side and upper guides,
also knife cutting block height.