Pushers won’t advance
when foot switch is
depressed.

(continued)

LS1 home switch.

Remove center panel on the
tabletop (section 18 drawing 2
detail #23). Located LS1 on the
left side of the air cylinder
Loosen the clamp, which
secures LS1 to the air cylinder.
Slide LS1 to the left or right until
the LED on LS1 illuminates.
Tighten clamp to secure to air
cylinder. Depress foot switch
and test for a completed cycle.
Replace tabletop.

Pushers advance then
stop.

LS2 needs to be adjusted.

Remove center panel on
tabletop (section 18 drawing 2
of 3 detail #23). Locate LS2 on
the right side of the air cylinder).
Loosen the clamp, which
secures LS2 to the air cylinder.
Close safety hood, turn power
on, press pusher advance key on
the keypad. This will advance
the pushers to the right. Slide
LS2 to the right or left until the
LED on LS2 illuminates.
Tighten clamp to secure LS2 to
the air cylinder. Depress pusher
key to return the pushers to their
home position. Depress foot
switch and test for a complete
cycle. Replace tabletop.

Pushers advance, safety
doors close, cycle stops.

Door switch IS2.

Check closing doors for any
obstruction.


PROBLEM

PROBABLE CAUSE

SOLUTION