Filter/regulator/lubicator (frl) – GBC Stl1000 User Manual

Page 39

Advertising
background image

38



1.

EMPTY WATER SEPARATOR DAILY


A.

To empty water separator, loosen bleeder valve located on the bottom of the water

separator.



2.

CHECK AIR LINE OILER WEEKLY


A.

Fill only with a good quality air tool oil.


B.

To fill with air tool oil:

1)

Disconnect air supply.

2)

Remove oil reservoir cup by turning a 1/4 turn, and then pull cup downward.

3)

Fill reservoir with good quality air tool oil to max line.

4)

Install oil reservoir.

5)

Connect air supply.



3.

OIL PUSHER AXLES BI-WEEKLY


A.

To oil pusher axles:

1)

Remove center tabletop by removing two end screws.

2)

Locate pusher axles.

3)

Apply two or three drops of 3&1 oil the length of each axle.

4)

Return center table and tighten in place.

WARNING: DO NOT APPLY GREASE OR HEAVY OIL. THIS WILL

DESTROY THE LINAR BEARINGS!!!







FILTER/REGULATOR/LUBICATOR (FRL)

The filter portion (see Figure 17-1) of the FRL is used to remove moisture from the compressed air
supply. Before the water level reaches the “MAX LEVEL” line (see figure 17-1), you should drain the
water. How often you have to drain depends on the amount of humidity in the air. To drain the filter,
turn the knob on the bottom of the filter in the “O” (open) direction. Turn the knob in the “S” (shut)

Advertising