Uneven wire closure, Wire closing with an over or under bite, Problem probable cause solution – GBC Stl1000 User Manual

Page 36

Advertising
background image

35

Uneven wire closure.

Anvil adjustment.

Loosen two socket head screws
at the back of the anvil. Adjust
anvil with the two hex head bolts
underneath the anvil to achieve
even end to end closure.
NOTE: Tighten socket head
screws after each adjustment to
insure accurate closure. Also
tighten jam nuts on the hex head
after final adjustment.

Wire closing with an
over or under bite.

Table straps.

Utilize one of two table straps to
control over or under bite.
There are two sizes of table
straps and two different
locations to mount them.
Experiment with the different
straps and locating positions.
The straps elevate the binding
edge of the book to control the
books influence in proper
closure of wire elements.

Pushers won’t advance
when foot switch is
depressed.

Main power.

Check main power switch
located on the main power box
is in the ON position.

E-STOP or Interlock switches.

Check E-STOP to insure it is in
the ON position and also check
all guards to be sure that they
are in their full closed position.

Main air supply.

Check airline connections.

Check air regulator is set at 80
psi.

PROBLEM

PROBABLE CAUSE

SOLUTION

Advertising