Motion control - simple, Slider/dolly time lapse calibration – Kessler MOTION CONTROL: Oracle Controller Full (3.02 SL) User Manual

Page 32

Advertising
background image

10.

Once your start point has been set, press the the MIDDLE

JOYSTICK BUTTON or ENTER to begin the calibration

11.

The screen will display

Slider On

with a countdown.

12.

Let the calibration complete. If you need to cut the calibration

short you can hit the MENU Button at any time.

NOTE:

The shorter the calibration time, the less accurate the calibration.

13.

To complete the calibration, measure the distance between

your start point (A) and ending point (B).

14

Move the joystick LEFT/RIGHT to adjust the values in the

ORACLE to match the distance in inches or centimeters that

the carriage moved during the calibration.

This number will vary in distance depending on your specific

setup / motor selection.

Press ENTER or the MIDDLE JOYSTICK BUTTON to confirm

15. Press

ENTER or the MIDDLE JOYSTICK BUTTON again to save

calibration data, or MENU to cancel calibration data.

Set Start Point

ENTER: Begin

Slider

6M 30S

Calibration

SLIDER/DOLLY TIME LAPSE CALIBRATION

MOTION CONTROL -

SIMPLE

CONTINUED

16.

Your system is now calibrated for accurate moves as the

ORACLE now knows how far over time the carriage will move

with setup used in calibration.

Quick Tip:

If moving between extreme environmental conditions, major camera

weight changes, or different incline angles, we recommend running the

calibration again to insure accuracy.

Adj Dist Moved

2.75IN

6.98CM