Pressure testing – La Cornue CornuFé 44 User Manual
Page 40
INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
38
Make sure the inner
rail is forwards
ArtNo.102-0011 - Pressure test point
Pressure Testing
Connect the appliance to the gas supply. Check the appliance
is gas sound.
The gas pressure can be measured at the pressure test point
on the appliance side of the pressure regulator (Fig.8-11).
For proper operation, the pressure of LP supplied to the
regulator must be between 10’’ and 13’’ of water column
(2.49 – 3.24 kPa).
When checking for proper operation of the regulator, the
inlet pressure must be at least 1’’ (0.25 kPa) greater than the
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the range
manifold must remain in the supply line regardless of
whether natural or LP gas is being used.
To Fit the Storage Drawer
Slide the inner side rails out until fully extended (Fig.8-12).
Lift the drawer at its sides and locate one of the drawer rails
(approximately 15 mm) onto an inner side rail (Fig.8-13).
Rotate the drawer to locate the remaining drawer rail onto
the opposite inner side rail.
Carefully slide the drawer back into the cavity. Some
resistance will be felt as the drawer rails locate fully onto the
inner side rails.
nn
Check the appliance is gas sound.
nn
DO NOT use a flame to check for gas leaks.
When using test pressures greater than ½ psig to pressure
test the gas supply system of the residence, disconnect the
range and individual shut-off valve from the gas supply
piping. When using test pressures of ½ psig or less to test
the gas supply system, simply isolate the range from the gas
supply system by closing the individual shut-off valve.
nn
Check the operation of all the burners.
Fig.8-11
Fig.8-12
15 mm
Approx.
Fig.8-13