Conversion to lp gas, Important, For your safety – La Cornue AlberTine 36 User Manual

Page 36: Conversion to propane, Orifices

Advertising
background image

INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

34

Burner head

Burner base

Brass venturi

Important

Observe all governing codes and ordinances.

The range must be properly grounded.

Save these instructions for the local electrical inspector’s

use.

When servicing or replacing gas carrying components

disconnect from gas before commencing operation and

check appliance is gas sound after completion. When

checking for gas leaks use a liquid leak detector at all joints

and connections to check for leaks in the system. Use a

product specifically manufactured for leak detection. Leak

testing of the appliance shall be conducted in accordance to

the manufacturer’s instructions.

For Your Safety

DO NOT store or use combustible materials, gasoline or other

flammable vapors and liquids in the vicinity of this or any

other appliance.

Conversion to Propane

This appliance is supplied set for Natural gas. A conversion kit

for Propane gas is supplied with the range.
If the appliance is to be converted this must be done before

installation. The conversion must be performed by a qualified

LP gas installer. After conversion the installation must comply

with the relevant regulations and also the local electricity

supply company requirements. Read the instructions before

converting this appliance.
Failure to convert the appliance correctly could invalidate any

warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest

of the appliance instruction, in particular for information on

Standards, range positioning, connection hose suitability, etc.
When servicing or replacing gas-carrying components

disconnect from gas before commencing operation and

check appliance is gas sound after completion.
DO NOT use reconditioned or unauthorized gas controls.

Orifices

Remove the burner heads. Undo the large brass nuts and

remove the brass venturis and rings (Fig.7-1).

Either:

Use a long socket wrench to access and remove the old

orifices.

Or:

Lift up the front of the maintop and prop it up at the

front. Remove the old orifices.

Save the orifices removed from the appliance for future use.

Install the new orifices; see Table 7-1 for orifice details.

7. Conversion to LP Gas

Natural Gas

Propane Gas

Center burner

205

118

Large Burners

150

99

Right front burner

112

68

Fig.7-1

Table 7-1