Setting

Display

FAN
Set the minimum percentage the fan should operate
while in the event. This provides ventilation for the
building. Each 10% is 6 minutes per hour.
Access Level: Installer, User

Range: Auto, 10 to 90%, ON

Conditions: Always available. 10 to 90% available
when Ventilation Mode is On.

Default: Auto

FAN
Set the minimum percentage the fan should operate while
in the event or Away scene. This provides ventilation
for the building. Each 10% is 6 minutes per hour.
Access Level: Installer, User

Range: Auto, 10 to 90%, ON

Conditions: Schedules used or Scenes set to Guest or
All. 10 to 90% available when Ventilation Mode is On.

Default: Auto

HUMIDITY MINIMUM
Set the minimum humidity level during the event.

Access Level: Installer, User

Range: OFF, 20 to 80%

Conditions: Humidify Mode set to HM1, 2, 3.

Default: 40%

HUMIDITY MAXIMUM
Set the maximum humidity level during the event.

Access Level: Installer, User

Range: 20 to 80%, OFF

Conditions: Dehumidify Mode set to DHM1, 2, 3, 4, 5. Default: 60%

HUMIDITY MAXIMUM AWAY
Set the maximum humidity level during Away scene.

Access Level: Installer

Range: 20 to 80%, OFF

Conditions: Dehumidify Mode set to DHM1, 2, 3, 4, 5. Default: OFF
HUMIDITY
Select if the humidification or dehumidification system
should operate during the event or away scene.
Access Level: Installer

Range: OFF or On

Conditions: Humidity Mode set to DHM1, 2, 3 or
Dehumidity Mode set to DHM1, 2, 3, 4, 5.

Default: OFF

Time Menu (1 of 2)

Setting

Display

MINUTES
Select the current time minutes.

Access Level: Installer, User

Range: 00 to 59

Conditions: Always available.

Default: 00

Set Temp Menu (4 of 4)