Tweco CutMaster 101 with SL100SV User Manual

Page 37

Advertising
background image

Manual 0-4642

3-13

INSTALLATION

3

5.

Connect the wire harness from the alternate CNC Control to the 20-position terminal strip (labeled 'J2') on the Automation
Interface PC Board. Refer to the illustration.

a. For divided voltage output, connect to terminals J2-11 (negative) and J2-9 (positive) on the Interface PC Board..

b. For raw arc voltage, connect to terminals E2 (positive) and E1 (negative) on the Output Power PC Board.

NOTE

There is no need to disconnect the factory-installed wire harness from the J4 terminal strip.

3

9

5

4

1

2

6

7

8

10

13

19

15

14

11

12

16

17

18

20

Art # A-04149

To

rch Switch

(P

ositiv

e)

To

rch Switch (Ne

gativ

e)

OK to

Mo

ve

OK to Mo

ve

Divided

Outpu

t (P

ositiv

e)

Divided Outpu

t (Negativ

e)

Logic Commo

n

Open

Open

Open

Open

Open

Open

Open

Open Arc

Vo

lts - P

ositiv

e (Propr

ietar

y)

Arc

Vo

lts Negativ

e - (Propr

ietar

y)

Remote Current Cont

rol (Optional)

Remote Current Cont

rol (Optional)

Remote Current Cont

rol (Optional)

To Main PC Board
Terminal J27-3

To Main PC Board
Terminal J27-1

To Main PC Board
Terminal J27-2

Installed only with

Optional Remote Current Control

Terminal Block J2

E2 (+)

E1(-)

Automation Interface PC Board

Output Power PC Board

Raw Arc Voltage
Connection Points

Alternate CNC Controller Connections to Automation Interface Board

6.

Tighten the through-hole protector ('strain relief') to secure the CNC cable to the power supply.

Advertising