Manual 0-4642

5-17

SERVICE

5

3. Faulty Logic PCB.

a. Measure for approximately 12 vdc between P1-7 and TP-1 on the Logic PCB.

• If 12 vdc is present, replace Logic PCB.

• If less than 2 vdc, replace Main PCB.

TP9

TP10

TP11

TP3

TP7

TP8

TP5

TP1

TP2

TP4

D13

TP6

Art # A-03654

D25

D33

P1-7

P1-9

Logic Board Layout