Cutmaster 35mm – Tweco CutMaster 35mm User Manual
Page 19
CUTMASTER 35MM
Manual 0-5082
INTRODUCTION
2-3
2.05 Input Wiring Specifications
CutMaster 35mm Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max I eff
Fuse
(amps)
Flexible Cord
(Min. AWG)
Flexible Cord
(Min. mm
2
)
3
Phase
380
50
18.4
28
25
32
10
6
400
50
18.7
27
24
32
10
6
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired
installations refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.
I1eff is taken at TDC 100% rated duty cycle.