Cutmaster 35mm, 01 unpacking, 02 lifting options – Tweco CutMaster 35mm User Manual

Page 25: 03 primary input power connections

Advertising
background image

CUTMASTER 35MM

Manual 0-5082

INSTALLATION

3-1

SECTION 3 SYSTEM:

INSTALLATION

3.01 Unpacking

1. Use the packing lists to identify and account for

each item.

2. Inspect each item for possible shipping damage.

If damage is evident, contact your distributor and

/ or shipping company before proceeding with

the installation.

3. Record Power Supply and Torch model and serial

numbers, purchase date and vendor name, in the

information block at the front of this manual.

3.02 Lifting Options

The Power Supply includes a handle for

hand lifting

only. Be sure unit is lifted and transported safely and

securely.

!

WARNING

Do not touch live electrical parts.
Disconnect input power cord before moving

unit.
FALLING EQUIPMENT can cause serious

personal injury and can damage equipment.
HANDLE is not for mechanical lifting.

• Only persons of adequate physical strength should

lift the unit.

• Lift unit by the handles, using two hands. Do not

use straps for lifting.

• Use optional cart or similar device of adequate

capacity to move unit.

• Place unit on a proper skid and secure in place

before transporting with a fork lift or other vehicle.

3.03 Primary Input Power Connections

CAUTION

Check your power source for correct voltage

before plugging in or connecting the unit.

The primary power source, fuse, and any

extension cords used must conform to local

electrical code and the recommended circuit

protection and wiring requirements as speci-

fied in Section 2.

The following illustration and directions are for wiring
three phase input power.

Art # A-08548

Input Power Cable Connections

Three-Phase (3ø)

GND

L1

L2

L3
L4

Three Phase Input Power Wiring

A. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power

supply and input cable before attempting

this procedure.

These instructions are for replacing the input power

and or cable for 400 VAC Power Supply to Three - Phase

input power.

1. Remove the Power Supply cover per instructions

found in section 5.

2. Disconnect the original input power cable from

the main input contactor and the chassis ground

connection.

3. Loosen the through - hole protector on the back

panel of the power supply. Pull the original

power cable out of the power supply.

4. Using a customer supplied four - conductor input

power cable for the voltage desired, strip back

the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.

Refer to Section 2 for power cable specifications.

Advertising