Art # A-07944

Hose Clamp

1/4 NPT to 1/4"

(6mm) Fitting

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

Optional Single - Stage Filter Installation

Installing Optional Two - Stage Air Filter Kit

This optional two - stage air line filter is also for use on

compressed air shop systems. Filter removes moisture

and contaminants to at least 5 microns.

Connect the air supply as follows:

1. Attach the Two Stage Filter bracket to the back

of the power supply per instructions supplied

with the filter assembly.

NOTE

For a secure seal, apply thread sealant to the

fitting threads according to manufacturer's

instructions. Do Not use Teflon tape as a

thread sealer as small particles of the tape

may break off and block the small air pas-

sages in the torch.

2. Connect the two stage filter outlet hose to the

inlet port of the Regulator / Filter Assembly.

3. Use customer - supplied fittings to connect the air

line to the Filter. A 1/4 NPT to 1/4" hose barbed

fitting is shown as an example.

Regulator

Input

Gas Supply

Hose

1/4 NPT to 1/4”

(6mm) Fitting

Regulator/Filter

Assembly

2-Stage Filter

Inlet Port (IN)

Outlet Port

(OUT)

Two Stage

Filter

Assembly

Art # A-07945_AC

Hose Clamp

Optional Two - Stage Filter Installation

Using High Pressure Air Cylinders

When using high pressure air cylinders as the air supply:

1. Refer to the manufacturer’s specifications for

installation and maintenance procedures for high

pressure regulators.

2. Examine the cylinder valves to be sure they are

clean and free of oil, grease or any foreign mate-

rial. Briefly open each cylinder valve to blow out

any dust which may be present.

3. The cylinder must be equipped with an adjust-

able high - pressure regulator capable of outlet

pressures up to 100 psi (6.9 bar) maximum and

flows of at least 300 scfh (141.5 lpm).

4. Connect supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at

the high pressure cylinder regulator.
Supply hose must be at least 1/4 inch (6

mm) I.D.
For a secure seal, apply thread sealant to the

fitting threads, according to manufacturer's

instructions. Do Not use Teflon tape as a

thread sealer, as small particles of the tape

may break off and block the small air pas-

sages in the torch.