CUTMASTER 35MM

SERVICE

Manual 0-5082

5-8

Optional Two-Stage Filter Element

Replacement

The Two-Stage Air Filter has two Filter Elements. When

the Filter Elements become dirty the Power Supply will

continue to operate but cut quality may become unac-

ceptable. Refer to Section 6, Parts List, for replacement

filter element catalog number.

1. Shut OFF primary input power.

2. Shut OFF air supply and bleed down system.

WARNING

Always turn OFF the air supply and bleed

the system before disassembling the Filter

Assembly as injury could result.

3. Loosen the two bolts on the top of the Filter As-

sembly enough to allow the Filter Elements to

move freely.

4. Note the location and orientation of the old Filter

Elements.

5. Slide out the old Filter Elements.

First & Second

Stage

Cartridges

(as marked)

Art # A-02942

Optional Two-Stage Filter Replacement

6. Slide the replacement Filter Elements into the

Filter Assembly, with the same orientation as

noted in Step 4 above.

7. Hand tighten the two bolts evenly, then torque

each bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper

torque may damage the gasket.

8. Slowly apply air pressure to the assembly, check-

ing for leaks.

NOTE

A small amount of air leakage from the bot-

tom fitting is normal.

This completes the parts replacement procedures.