Manual 0-5141 2-1 INTRODUCTION

SECTION 2 SYSTEM: INTRODUCTION

2.01 Working Principle

Rectifier

Inverter

Transformer

Rectifier

Reduce pressure, filter

Gas valve

Cutting torch

Workpiece

Compressed air

Art # A-09204_AB

2.02 Power Supply Specifications

CUTMASTER 42 Power Supply Specifications

Input Power

120 VAC (+-10%), 1Phase, 50/60Hz

208-230 VAC (+-10%), 1Phase, 50/60Hz

Output Current

20 Amps @ 120VAC, 15A

20-27 Amps @ 120VAC, 20A

20-40 Amps @ 230VAC, 20A

CUTMASTER 42 Power Supply Duty Cycle (Note 1)

Ambient Temperature

104° F (40° C)

Duty Cycle

30% @ 120VAC, 40% @ 230VAC

Rated Current

27 Amps @ 120VAC, 40 Amps @ 230V

SL40 Torch Gas Requirements (see section 2T.03)

Notes

1. Duty Cycle is the percentage of time the system can be operated without overheating. Duty cycle is re-

duced if primary input voltage (AC) is low or the DC voltage is higher than shown in this chart.
2. Air supply must be free of oil, moisture, and other contaminants. Excessive oil and moisture may cause

double-arcing, rapid tip wear, or even complete torch failure. Contaminants may cause poor cutting perfor-

mance and rapid electrode wear. Optional filters provide increased filtering capabilities.

NOTE

IEC Rating is determined as specified by the International Electro-Technical Commission. These

specifications include calculating an output voltage based upon power supply rated current. To facilitate

comparison between power supplies, all manufacturers use this output voltage to determine duty cycle.
TDC Rating is determined using an output voltage representative of actual output voltage during cutting

with a TDC torch. This voltage may be more or less than IEC voltage, depending upon choice of torch,

consumables, and actual cutting operation.