03 input wiring specifications, 04 power supply features, Cutmaster 42 – Tweco 42 CutMaster Operating Manual User Manual

Page 11: Caution

Advertising
background image

CUTMASTER 42

CUTMASTER 42

INTRODUCTION 2-2 Manual 0-5141

Manual 0-5141 2-3 INTRODUCTION

Art# A-09333_AC

26lb / 11.8kg

7" (177mm)

18.5" (469.9mm)

9" (228.6mm)

CUTMASTER

®

42

120V 15A

120V 20A

230V 20A

A

24

40

20

20

30

27

Figure 2-1: Power Supply Dimensions & Weight

NOTE

Weight includes torch & leads, input power cord, and work cable with clamp.

CAUTION

Provide clearance for proper air flow through the power supply. Operation without proper air flow will

inhibit proper cooling and reduce duty cycle.

2.03 Input Wiring Specifications

CUTMASTER 42 Input Power Requirements

Input

Power Input

Current Input

Current Input

Suggested Sizes (See Note)

Voltage

Freq.

(kVA)

Max (Amps)

Ieff (Amps)

Fuse (Amps)

(Volts-AC)

(Hz)

1-Ph

1-Ph

1-Ph

1-Ph

120

50/60

3.3

27.5

15

25

208

50/60

5.0

24

15.4

23

230

50/60

5.0

21.4

13.5

20

240

50/60

5.0

20.8

13

20

Line Voltages with Suggested Circuit Protection
Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements for your situation

in this regard.

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations.

Cable conductor temperature used is 167° F (75° C).

2.04 Power Supply Features

Air Inlet

Control Panel

Torch Lead

120/230 VAC Power Source

Work Cable and Clamp

Art # A-09334_AC

CUTMASTER

®

42

120V 15A

120V 20A

230V 20A

A

24

40

20

20

30

27

Art# A-09335

Air Inlet

On/Off

Switch

Power Cord

Advertising