Section 2torch: introduction, 2t.01 scope of manual, 2t.02 specifications – Tweco 42 CutMaster Operating Manual User Manual

Page 13: Cutmaster 42

Advertising
background image

Manual 0-5141 2T-1 INTRODUCTION

CUTMASTER 42

SECTION 2 TORCH:

INTRODUCTION

2T.01 Scope of Manual

This manual contains descriptions, operating instructions and

maintenance procedures for the SL40 Plasma Cutting Torch.

Service of this equipment is restricted to properly trained

personnel; unqualified personnel are strictly cautioned against

attempting repairs or adjustments not covered in this manual,

at the risk of voiding the Warranty. Read this manual thoroughly.

A complete understanding of the characteristics and capabili-

ties of this equipment will assure the dependable operation for

which it was designed.

2T.02 Specifications

A. Torch Configurations

1. Hand Torch, Model SL40

The hand torch head is at 75° to the torch handle. The

hand torches include a torch handle and torch trigger

assembly.

8.3" (210.82mm)

2.6"

(66.04mm)

.96" (24.38mm)

Art # A-09336

B. Torch Leads Lengths

Hand Torches are available as follows:
• 15 ft / 4.6 m.

C. Torch Parts (see Section 6.03)

Starter Cartridge, Electrode, Tip, Shield Cup

D. Parts - In - Place (PIP)

Torch has built-in switch.

12 vdc circuit rating

E. Type Cooling

Combination of ambient air and gas stream through torch.

F. Torch Ratings

SL40 Torch Ratings

Ambient

Temperature

104° F

40° C

Duty Cycle

100% @ 40 Amps @ 193 scfh

Maximum Current

40 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

500V

Torch Control Circuit

Voltage

24V

G. Current Ratings

SL40 Current Ratings

SL40 Torch & Leads

Up to 40 Amps, DC,

Straight Polarity

NOTE

Power Supply characteristics will determine

material thickness range.

H. Gas Requirements

SL40 Torch Gas Specifications

Gas (Plasma and Secondary)

Compressed Air

Minimum Input Pressure

85 psi

5.9 bar

Maximum Input Pressure

125 psi / 8.6 bar

Gas Flow

193 scfh

91 lpm

!

WARNING

This torch is not to be used with oxygen

(O

2

). This torch is not to be used with high

frequency starting systems.

Advertising