03 primary input power connections, Cutmaster 42 – Tweco 42 CutMaster Operating Manual User Manual

Page 16

Advertising
background image

CUTMASTER 42

CUTMASTER 42

INSTALLATION 3-2 Manual 0-5141

Manual 0-5141

3-3 INSTALLATION

3.03 Primary Input Power Connections

Power Cords Included With Power Supply

Attached to the power supply is an input power cord with a 230 Volt 50 Amp NEMA 6-50P for plug. Supplied adapters allow for

connection of the power supply input cable plug when using 120V input power.

Art# A-09432_AB

Figure 3-1: 120VAC Adapter Pigtail

CAUTION

Check your power source for correct voltage before plugging in or connecting the unit. The primary

power source, fuse, and any extension cords used must conform to local electrical code and the rec-

ommended circuit protection and wiring requirements as specified in Section 2.

Input Voltage (VAC)

Rated Output

Amps (RMS) input at rated

output, 60 Hz, single-phase

kVA

120V, 15A Circuit

20A, 88V

20.4

2.5

120V, 20A Circuit

27A, 91V

28.5

3.5

120V, 30A Circuit

27A, 91V

28.5

3.5

208-230V, 20A Circuit

40A, 96V

23-21.4

4.8

3.04 Air Supply Connections

A. Connecting Air Supply to Unit

The connection is the same for compressed air or industrial compressed air in gas cylinders.

1. Connect the gas line to the compressed air inlet port at the appropriate pressure.

Art# A-09337

Air Inlet

On/Off

Switch

Figure 3-2: Gas Connection to Compressed Air input

B. Using Industrial Compressed Air In Gas Cylinders

When using Industrial compressed air in gas cylinders as the gas supply:

1. Refer to the manufacturer’s specifications for installation and maintenance procedures for high pressure gas regulators.

2. Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign material. Briefly open each

cylinder valve to blow out any dust which may be present.

3. The cylinder must be equipped with an adjustable high - pressure regulator capable of outlet pressures up to 100 psi

(6.9 bar) maximum and flows of at least 250 scfh (120 lpm).

4. Connect gas supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at the high pressure gas cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm) I.D.
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions.

Do Not use Teflon tape as a thread sealer, as small particles of the tape may break off and block the

small gas passages in the torch.