Cutmaster a120 – Tweco A120 CutMaster User Manual
Page 17

CUTMASTER A120
Manual 0-4989
INTRODUCTION
2-3
2.05 Input Wiring Specifications
CutMaster A120 Power Supply Input Cable Wiring Requirements
Input
voltage
Freq
Power
Input
Suggested Sizes
Volts
Hz
kVA
I max
I eff
Fuse
(amps)
Flexible Cord
(Min. AWG)
Flexible Cord
(Min. mm
2
)
1 Phase
208
60
26.2
126
98
150
4 Type W
25 Type W
230
60
27.6
118
95
125
4 Type W
25 Type W
460
60
35
76
68
100
4
25
3 Phase
208
60
21.6
60
55
60
4
25
230
60
22.3
56
50
60
4
25
380
50
23
35
32
40
8
10
400
50
23.6
34
31
40
8
10
460
60
29.5
37
33
40
8
10
600
60
29.0
28
25
30
10
6
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.
I1eff is taken at TDC 100% rated duty cycle