CUTMASTER A120

OPERATION

Manual 0-4989

4T-64

Mild Steel
120A
Air Plasma / Air Shield

Shield Cap

Maximum Life Shield Cup

Tip

Starter Cartridge

Heavy Duty Starter

Cartridge

Electrode

9-8256

9-8237

9-8233

9-8213

9-8277

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc Voltage

Torch

Working

Height

Travel Speed

Initial

Piercing

Height

Pierce Delay

Kerf Width

@ Rec.

Speed

(GA) (in)

inch

PSI

(torch lead

length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

1/4

0.250

80 (25')

80 (50')

139

0.125

160

0.20

0.20

0.11

3/8

0.375

140

0.125

85

0.20

0.20

0.11

1/2

0.500

142

0.125

75

0.20

0.50

0.10

5/8

0.625

144

0.125

45

0.20

0.70

0.11

3/4

0.750

150

0.125

30

0.25

1.50

0.12

7/8

0.875

158

0.175

25

Edge Start

0.13

1

1.000

160

0.175

22

Edge Start

0.14

1-1/4

1.250

165

0.175

15

Edge Start

0.17

1-1/2

1.500

171

0.175

8

Edge Start

0.15