CUTMASTER A120
OPERATION
Manual 0-4989
4T-32
Mild Steel
120A
Air Plasma / Air Shield
Deflector
Standard Shield Cup
Maximum Life Shield Cup
Tip
Starter Cartridge
Heavy Duty Starter
Cartridge
Electrode
9-8243
9-8218
9-8237
9-8233
9-8213
9-8277
9-8232
Material
Thickness
Gas Pressure
(Air)
Arc Voltage
Torch
Working
Height
Travel Speed
Initial
Piercing
Height
Pierce Delay
Kerf Width
@ Rec.
Speed
(GA) (in)
inch
PSI
(torch lead
length)
Volts
(in)
(ipm)
(in)
(sec)
(in)
1/4
0.250
80 (25')
80 (50')
134
0.19
150
0.25
0.10
0.11
3/8
0.375
141
0.19
85
0.25
0.30
0.11
1/2
0.500
141
0.19
70
0.25
0.80
0.12
5/8
0.625
146
0.19
45
0.25
1.00
0.12
3/4
0.750
150
0.19
30
0.25
1.20
0.12
7/8
0.875
160
0.25
25
Edge Start
0.14
1
1.000
163
0.25
19
Edge Start
0.14
1-1/4
1.250
168
0.25
12
Edge Start
0.15
1-1/2
1.500
172
0.25
8
Edge Start
0.16