INSTALLATION PROCEDURES

12

Manual 0-2641

A-01794

Rear Panel

Rear Panel

Screws (4 Places)

Figure3-1 Rear Panel Removal

3. Remove the eight screws securing the Right and

Left Side Panels to the unit.

A-01802

Right Side Panel

Screws (4 Places)

Left Side Panel

Screws (4 Places)

Figure 3-2 Side Panel Screw Removal

4. Pull the two Side Panels out the back of the unit.

A-01803

Side Panel

(Right)

Side Panel

(Left)

Figure 3-3 Side Panel Removal

5. Select a flat, horizontal, mounting surface for the

unit.

6. Using the full size template on the last page of this

Manual mark the location of the four mounting
holes.

7. Drill four 9/32 inch holes at the marked locations.

6. Mount the unit to the surface using four 1/4-20

bolts, lock washers and flat washers provided. For
convenience two different lenghts have been pro-
vided (3/4 and 1-1/2 inches).

NOTE

There are four holes provided in the base of the Gas
Control Module. Use only these four holes for
mounting the unit.

1/4" Mounting Bolts,

Lock Washers and

Flat Washers (4 Places)

A-01804

Figure 3-4 Mounting Hardware Installation