Section 4: operation, 01 introduction, 02 functional overview – Tweco GCM-6000 Gas Control User Manual

Page 25: 03 operating controls & indicators, A. front panel, Figure 4-1 front panel operating controls

Advertising
background image

Manual 0-2641

19

OPERATION

SECTION 4:

OPERATION

4.01 Introduction

This Section provides a description of the Gas Control
Module.

4.02 Functional Overview

The Gas Control Module GCM 6000 provides all Plasma
and Secondary gas selection and control instrumentation
remote from the system power supply.

The Gas Control Module extends the necessary system
gas controls away from the power supply and is a re-
quired accessory with Merlin 6000GST Cutting Systems.
There are various Front Panel controls and indicators used
to set gas pressures and flows. The Rear Panel has con-
nections for the gas control cable and preflow, plasma,
and secondary gas to be used.

4.03 Operating Controls &

Indicators

A. Front Panel

PREFLO

W

PLASMA

PREFLO

W

PLASM

A

SECOND

AR

Y

MODE

PLASMA

SECOND

AR

Y

RU

N

PILO

T SET

PLASMA SET

SEC SET

AIR

AIR

OT

HE

R

Gas Contr

ol Module

O

2

2

N

2

Ar/H

2

N

H

2

0

G

C M

6

0 0

0

4

5

11

10

6

8

1

9

2

7

A-01793

3

Figure 4-1 Front Panel Operating Controls

1. MODE Selection Switch

The switch selects one of four setup and operation
modes:

• RUN

• PILOT SET

• PLASMA SET

• SEC SET (Secondary)

2. PLASMA Gas Selection Switch

The switch selects one of four plasma gases for the
operation.

• AIR

• O

2

(Oxygen)

• N2 (Nitrogen)

• Ar/H2 (Argon/Hydrogen)

3. SECONDARY Gas Selection Switch

The switch selects one of four secondary gases for the
operation.

• AIR

• N2 (Nitrogen)

• OTHER

• H

2

O (Water)

4. PREFLOW Gas Flowmeter

Flowmeter used to adjust the flow of the preflow gas
to the system.

5. PLASMA Gas Flowmeter

Flowmeter used to adjust the flow of the plasma gas
to the system.

6. SECONDARY Gas Regulator

Adjusts secondary gas pressure. Pull knob out and
turn clockwise to increase secondary pressure to de-
sired level.

7. SECONDARY Gas Pressure Gauge

Indicates secondary gas pressure from 0 - 160 psi (0 -
11 bar).

8. PLASMA Gas Regulator

Adjusts plasma gas pressure. Pull knob out and turn
clockwise to increase secondary pressure to desired
level.

Advertising