INSTALLATION PROCEDURES

16

Manual 0-2641

If the Gas Control Module serial number ends with
the letter 'B' or earlier install additional parts per
the following:

a. Locate the short wiring harness and inline splice

supplied with the option.

b. Inside the Gas Control Module locate E26 in

the lower right hand corner (viewed from the
rear of the unit) of the PC Board.

c. Place the inline splice over the wire connected

to E26.

Wire From Option

Wire Harness (Short)

Existing Wire

(From GCM Harness

at PC Board E26)

Crimp Closed

A-02383

Figure 3-12 Inline Splice Installation,

d. Place the free end of the single wire #24 from

the short wiring harness into the other slot of
the inline splice.

e. Close the inline splice making sure that it snaps

closed.

Mating Plug From

GCM Wiring Harness

Connector From

Option Wiring Harness

A-02377

Figure 3-13 Wiring Harness Connections

f. Remove the two nuts from the ground stud at

the rear of the Gas Control Module.

g. Pull the groud stud out of the panel and place

the wire with the ring terminal over the stud.
Insert the stud back into the panel hole and
secure with the two nuts removed above.

h. Connect wire #110 with piggy-back faston to

one of the tabs on the the Water Solenoid Valve.

11. Install the Right Side Panel from the Gas Control

Module to the right side of the Optional Second-
ary Gas/Water Flow Control Module.

Screws

(4 Places)

Right Side

Panel

A-02378

Figure 3-14 Right Side Panel Installation

12. Reinstall the Left Side Panel and then the Rear

Panel to the Gas Control Module.

13. Reinstall the Rear Panel to the Optional Second-

ary Gas/Water Flow Control Module.