13

INSTALLATION PROCEDURES

7. Before tighting the bolts make sure that the unit

Flowmeters are plumb.

8. Tighten the four bolts to secure the unit to the

mounting surface.

9. Reinstall the Side and Rear Panels (see Note).

NOTE

If the Optional Secondary Water Control is to be
installed, then continue with Section 3.07 before
reinstalling the Side and Rear Panels.

3.06 External Cable And Hose

Connections

The Gas Control Module has the following connections:

• Three input gas connections

• Three output gas connections

• Control cable connections

• Grounding stud

NOTE

For proper connection of the cables and hoses to
the Power Supply and Arc Starter Box refer to the
Manuals supplied with those units.

1. Connect the Gas Control Cable to the rear of the

Master Power Supply 'GAS CONTROL J55' con-
nector.

2. Connect the other end of the Gas Control Cable to

'FROM POWER SUPPLY J56' connector at the rear
of the Gas Control Module.

NOTE

Gas hoses from the Gas Control Module to the Arc
Starter Box are marked on both ends with a blue
band. Each band is marked with 'RAS' (Remote
Arc Starter). The hoses between the Gas Control
Module and the Power Supply are not marked.

3. Connect the Plasma Gas Hose to the internal bulk-

head connection of the Master Power Supply.

4. Connect the other end of the hose to the 'FROM

POWER SUPPLY PLASMA' connection at the rear
of the Gas Control Module.

5. Connect the Secondary Gas Hose to the internal

bulkhead connection of the Master Power Supply.

6. Connect the other end of the hose to the 'FROM

POWER SUPPLY SECONDARY' connection at the
rear of the Gas Control Module.

7. Connect the Preflow Gas Hose to the internal bulk-

head connection of the Master Power Supply.

8. Connect the other end of the hose to the 'FROM

POWER SUPPLY PREFLOW' connection at the
rear of the Gas Control Module.

Gas Control

Cable

Secondary Gas Hose

(Left-Hand Thread)

Plasma

Gas Hose

Preflow

Gas Hose

A-01806

Rear Panel

J56

Figure 3-5 Connections From Master Power Supply

9. Connect the Arc Starter Control Cable to the 'TO

ARC STARTER BOX J57' connector at the rear of
the Gas Control Module.

10. Connect the other end of the Arc Starter Control

Cable to connector J58 at the end of the Arc Starter
Box.

11. Connect the Plasma RAS Gas Hose to the 'TO

ARC STARTER BOX PLASMA' connection at the
rear of the Gas Control Module

12. Connect the other end of the Plasma RAS Gas

Hose to the mating connector at the end of the Arc
Starter Box.

13. Connect the Secondary RAS Gas Hose to the 'TO

ARC STARTER BOX SECONDARY' connection at
the rear of the Gas Control Module

14. Connect the other end of the Secondary RAS Gas

Hose to the mating connector at the end of the Arc
Starter Box.

15. Connect the Preflow RAS Gas Hose to the 'TO

ARC STARTER BOX PREFLOW' connection at the
rear of the Gas Control Module

Advertising