2-2

Manual 0-2690

3. Torch Ratings

Ambient

Temperature

104° F

(40° C)

Duty Cycle

100% @ 300 Amps @ 0.5 gpm

(1.89 lpm) Coolant Flow Rate

Maximum Current

300 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

12 kV

Torch Ratings

4. Cutting Range

• Production speed cutting:

3/4 inch (19 mm) at 150A

1 inch (25.4 mm) at 300A

• Maximum capacity when edge starting:

2 inch (50.8 mm)

5. Pierce Rating

3/4 inch (19 mm) at 150A

1 inch (25.4 mm) at 300A

6. Transfer Distance

3/8 inch (10 mm)

7. Torch Parts

Gas Distributor, Electrode, Tip, Shield Cup Body,
End Cap

8. Plasma Gas Requirements

a. Plasma Gas:

Compressed Air, Oxygen (O2),

Nitrogen (N2), or Argon/Hydrogen (Ar/H2)

b. Pressure:

75 to 100 psi (5.2 to 6.9 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 bar)

c. Cold Flow - Cutting:

60 to 135 scfh (28.3 to

64.6 lpm)

scfh = standard cubic feet per hour

NOTE

Cold flow is measured before the main arc is acti-
vated. When pressure is set correctly the plasma
gas flow rate is significantly lower when the arc is
initiated.

9. Secondary Gas Requirements

a. Secondary Gas:

Compressed Air, Carbon Di-

oxide (CO

2

) or Nitrogen (N2)

b. Pressure:

15 to 80 psi (1.0 to 5.5 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 bar)

c. Flow - Cutting:

15 to 400 scfh (7.1 to 189 lpm)

scfh = standard cubic feet per hour

10. Secondary Water Requirements

a. Water Source

(See Notes): Clean drinking

quality tap water can be used as a secondary

b. Water Pressure:

Minimum 50 psi (3.5 bar)

c. Water Flow - Cutting:

3 - 9 gph (13 - 40 lph)

NOTES

Tap water should only be used as a secondary on
machine torches.

The tap water source does not need to be deionized,
but in water systems with extremely high mineral
content a water softener is recommended.

Tap water with high levels of particulate matter
must be filtered.

11. Preflow Gas Requirements

a. Preflow Gas:

Nitrogen is the only recom-

mended preflow gas

b. Pressure:

90 to 115 psi (6.2 to 7.9 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 bar)

c. Flow - Cutting:

42-85 scfh (19.8 to 40.1 lpm)

scfh = standard cubic feet per hour

12. Weight (without leads)

2.0 lb (0.91 kg)