Appendix 1: sequence of operation block diagram – Tweco 6000GST Cutting Systems User Manual

Page 47

Advertising
background image

Manual 0-2690

A-1

APPENDIX

APPENDIX 1: SEQUENCE OF OPERATION BLOCK

DIAGRAM

A-01815

ACTION

Close external

disconnect switch

RESULT

• Power to system

ACTION

Enable ON at Remote

or TB2

ON/OFF switch to ON

RESULT

• AC indicator ON

• TEMP indicator ON

• GAS indicator ON

• Fan and Pump ON

• 40 sec auto-purge

ACTION

Gas Control Module

MODE switch to SET

RESULT

• Gas solenoids open,

gases flow to set

pressures and flows
• GAS indicator ON

ACTION

Gas Control Module

MODE switch to RUN

RESULT

• Gas flow stops

• GAS indicator OFF
• Power circuit ready

ACTION

Proctect eyes and

activate torch

RESULT

• GAS indicator ON

• Gas pre-flow

• Main contactor

closure

• DC indicator ON

• Pilot contactor

closes

• PILOT indicator ON

• Pilot arc established

PILOT ARC

ACTION

Torch removed from

work

RESULT

• Main arc stops

• Pilot arc auto-restart

if enabled

• PILOT indicator ON

ACTION

Torch moved to

within

1/8 - 3/8 inch of

work

RESULT

• Main arc transfer

• PILOT indicator OFF

• Pilot arc off

ACTION

Open external

disconnect

RESULT

• No power to system

ACTION

ON/OFF switch

to OFF

RESULT

• AC indicator OFF

• TEMP indicator OFF

• Fan and Pump OFF

ACTION

Torch de-activated (by torch switch

release or by remote device)

RESULT

• Main arc stops

• Main contactor opens

• DC indicator OFF

• Pilot and PILOT indicator OFF

NOTE - If torch is activated during post-flow

the pilot arc will immediately restart. If within

range of the work, main arc will transfer.

After post-flow:

• Gas solenoids close, gas flow stops

• GAS indicator OFF