03 specifications & design features, 03 specifications & design features -2 – Tweco 1000 Merlin(Dec2004) User Manual

Page 16

Advertising
background image

INTRODUCTION

2-2

Manual 0-2708

B. Requirements to Complete System

To complete the system, the user needs to provide the
following:

• Primary Input Power Cable

• Gas Supplies

2.03 Specifications & Design

Features

The following specifications apply to the Power Supply
only:

1. Front Panel Controls

• ON/OFF and RUN/SET Switches

• Output Current Control

• Work Cable Connection

• Torch Leads Connection

2. Front Panel Indicators

• AC

• TEMP

• GAS Pressure/Coolant Flow

• DC Output

3. Gas Control Panel

• Plasma and Secondary Gas Pressure Controls and

Gauges

• Plasma Gas Flowmeter

• Secondary Lo-Flow Gas Flowmeter

• Secondary Mode Selector Switch

• Secondary Water Mist Flowmeter

4. Rear Panel

• Primary Input Power Cable Strain Relief

• Plasma Gas Supply Connection

• Secondary Gas Supply Connection

• Secondary Water Supply Connection

• Dual Stage Air Filter

• CNC Control Connector

5. Input Power (see NOTES)

208/230/240 VAC (±10%), 50/60 Hz, Three-Phase

380-415 VAC (±10%), 50/60 Hz, Three-Phase

460 VAC (±10%), 50/60 Hz, Three-Phase

575 VAC (±10%), 50/60Hz, Three-Phase

NOTES

Refer to Appendix 1 for suggested input wiring
size, current ratings and circuit protection require-
ments.

Units using 575 VAC input power require instal-
lation of Optional 575 V Transformer Assembly.

6. Output Power

Continuously variable from 30 to 100 amps (±5%)

7. Duty Cycle (see NOTE)

NOTE

The duty cycle will be reduced if the primary in-
put voltage (AC) is low or the DC voltage is higher
than shown in the chart.

Ambient

Temperature

104° F (40° C)

Duty Cycle

100%

Current

100 Amps

DC Voltage

130 vdc

Power Supply Duty Cycle

8. Cut Capacity

Pierce and Production Rating: 1/2 inch (12.7 mm)

9. Pilot Circuitry

Capacitive Discharge (CD), Pulsed DC (See Note)

NOTE

Optional Remote Arc Starter available.

10. CNC Interface Signals

Start/Stop and OK-To-Move

11. Coolant Pressure

Internal Service-adjustable

130 psi (8.8 bar) at zero flow

120 - 125 psi (8.2 - 8.5 bar) at 0.6 gpm (2.3 lpm)

Advertising