INSTALLATION

3-4

Manual 0-2708

7. Reinstall the star washers and nuts.

8. Tighten all the nuts.

NOTE

If changing from low voltage to HIGH VOLTAGE
all nuts must be tightened even if not used on the
terminal block.

9. Insert the single wire voltage selection plug into the

auxiliary transformer input connector.

Auxilliary Transformer
Input Connector

Voltage

Selection

Plug

Terminal

Block

Voltage Selection

Block

A-02071

SEE OPERA TING MANU

AL FOR

INST ALLA

TION INSTRUCTIONS

A

UX.

TRANS

.

HIGH VO

L TA

GE

208V/230V

Nuts and Star Washers

Figure 3-3 Low Voltage Configuration

3.07 Input Power Cable

Connections

WARNING

Disconnect primary power at the source before con-
necting the primary power cable to the power sup-
ply.

The primary power cable must be supplied by the end
user and installed to the power supply assembly. Refer
to Appendix 1 for suggested cable sizes.

A. Primary Power Cable Connection

Procedure

1. Route the primary power cable through the strain re-

lief fitting in the rear panel of the power supply and
tighten strain relief screws.

AC Input Cable

Strain Relief

AC Input

Power Cable

A-02159

Figure 3-4 AC Input Power Cable Strain Relief