APPENDIX 1: INPUT WIRING REQUIREMENTS

NOTES

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations refer
to local or national codes.

Cable conductor temperature used is 167° F (75° C).

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER

use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.

Input

Power Input

Current

Suggested Sizes (See Notes)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

Wire (Canada)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

208

50/60

23.4

65

90

2

2

220

50/60

24

63

90

2

2

230

50/60

24.7

62

80

2

2

240

50/60

24.9

60

80

2

4

380

50/60

24.4

37

50

6

6

415

50/60

24.4

34

50

6

8

460

50/60

24.7

31

45

6

8

575

Requires Transformer Module

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code