Manual 0-2708
A-3
APPENDIX
APPENDIX 3: TYPICAL MECHANIZED SYSTEM
GROUNDING DIAGRAM
Standoff Control
Earth
Ground
Plasma Power
Supply
Work Cable
Workpiece
Earth
Ground
3-Phase
Input
A-02176
CNC Control
Earth
Ground
NOTE
Work Cable must connect direct to workpiece.
DO NOT connect Work Cable to earth ground and then to workpiece.
CNC Control