11 torch and torch leads extension connection, 11 torch and torch leads extension connection -10 – Tweco 3000 Merlin User Manual

Page 28

Advertising
background image

INSTALLATION

3-10

Manual 0-2532

D. Plasma and Secondary Gases With

Optional Gas Control

The required plasma and secondary gases are connected
to the rear of the Power Supply. The secondary selec-
tion switch on the front panel of the Power Supply must
always be set to GAS for all secondary gases when the
Gas Control Option is installed. The type of gas to be
used will be selected at the Gas Control Option front
panel.

1. Connect the required plasma gases to the op-

tional Gas Control gas manifold.

NOTE

If compressor shop air is to be used as the
plasma gas the line must be filtered.

OUTPUT

TO

CONTROL

CONTROL
MODULE

MODULE

AIR

PLASMA
INPUT

N2

PLASMA
INPUT

O2

PLASMA
INPUT

PLASMA GAS

Ar/H

2

PLASMA
INPUT

To Plasma Gas

Input Fitting

Plasma Gas Output

From Gas Select Option

}

From Plasma

Gas Supplies

A-01006

Figure 3-12 Plasma Gas Connections

2. Connect the required secondary gases the SEC-

ONDARY INPUT fittings marked OTHER, N2, and
SECONDARY GAS (air).

NOTE

If air is to be used as the secondary gas it
should be connected to the fitting marked
SECONDARY GAS.

OUTPUT

OUTPUT

TO

CONTROL

CONTROL
MODULE

MODULE

AIR

PLASMA

INPUT

N

2

PLASMA

INPUT

O

2

PLASMA

INPUT

PLASMA GAS

Ar/H

2

PLASMA

INPUT

OTHER Secondary

Gas Supply

N2 Secondary

Gas Supply

AIR Secondary

Gas Supply

A-01005

Figure 3-13 Secondary Gas Connections

3.11 Torch and Torch Leads

Extension Connection

The Torch Leads Extension connects directly to a bulk-
head inside the Power Supply. Connect the Torch Leads
Extension per the following procedure:

1. Open the front panel access panel to gain ac-

cess to the bulkhead.

2. Remove the tape securing the shield of the torch

leads extension to the leads.

3. Unfold the shield towards the end of the leads.

4. Feed the torch leads extension through the boot

on the front panel of the Power Supply.

5. Feed the torch leads extension through the sup-

plied Hose Clamp.