4-10

Manual 0-2532

Auto-Restart

Mode

SW2-1

Position

SW2-2

Position

Normal *

0 (Off)

0 (Off)

Delayed

0 (Off)

1 (On)

Delayed

1 (On)

0 (Off)

Delayed

1 (On)

1 (On)

* = Factory Setting

C. Gas Pre-Flow Delay (SW3)

ON

OFF

1 2

SW3

A-00993

Logic PC Board

Figure 4-10 Gas Pre-Flow Delay Switch SW3

Location

The pre-flow delay allows time for gases to flow to
the torch when the torch is activated. Pre-flow is im-
mediately followed by pilot arc initiation. Pre-flow is
factory-set at 2 seconds, but can be reset to 4, 7, or
10 seconds as desired. Extended torch leads may
require longer pre-flow durations.

Pre-Flow Time

(Seconds)

SW3-1

Position

SW3-2

Position

2 *

0 (Off)

0 (Off)

4

0 (Off)

1 (On)

7

1 (On)

0 (Off)

10

1 (On)

1 (On)

* = Factory Setting

D. Gas Post-Flow Delay (SW4)

ON

OFF 1 2

SW4

A-00994

Logic PC Board

Figure 4-11 Gas Post-Flow Delay Switch SW4