07 voltage selection – Tweco Merlin 6000 Master PS User Manual

Page 21

Advertising
background image

Manual 0-2568

3-3

INSTALLATION PROCEDURES

B. Input Voltage Selection

Every Power Supply is factory-wired for 460V three-phase
input. For any other input voltage, the Power Supply
must be changed using the procedures in Section 3.07.

C. Opening Power Supply Enclosure

The left side panel (viewed from the front) of the Power
Supply must be removed to make electrical connections
and to select the proper input voltage.

WARNING

Disconnect primary power at the source before as-
sembling or disassembling power supply, torch
parts, or torch and leads assemblies.

1. Remove the ten screws which secure the left side panel

(viewed from the front) to the Power Supply .

Left Side Panel

Screws

(10 Places)

A-01535

Figure 3-3 Opening Power Supply

2. Remove the left side panel from the Power Supply.

3.07 Voltage Selection

The Power Supply can be wired to use input voltages
from 200 - 575 VAC. Power Supply is factory-wired for
460 VAC, three-phase input. Voltage selection is accom-
plished by switching busbar connections on the input
voltage terminal board inside the Power Supply.

1. Locate the input voltage terminal board on the

left side of the power supply.

Input Voltage

Terminal Board

L1

L2

L3

Busbars

A-00985

Extra Busbar

Storage Location

Figure 3-4 Input Voltage Terminal Board Location

NOTE

Extra busbars are attached (stored) to the top side
of the power transformer assembly.

2. Check the busbar configuration on the input volt-

age terminal board . The busbar configuration
must correspond with the available line voltage
per the following figure and the label inside the
unit:

Advertising