OPERATION

4-2

Manual 0-2568

5. Power Lead Strain Relief

Strain relief to secure the power lead to the Power
Supply after it is installed.

6. Secondary Water Flowmeter/Regulator

Used to adjust and monitor the flow of the second-
ary water from 0 - 10 gph (0 - 44 lph).

B. Control Front Panel

NOTE

This panel is the access cover to the Logic Control
PC Board.

1. ON/OFF Switch

ON position activates all system control circuits when
remote or CNC enable is ON.

OFF position deactivates control circuits.

2. RUN/SET/PURGE Switch

RUN position is used for torch operation.

SET position is used for setting gas pressures.

PURGE position is for purging the plasma gas line.

3. Current Control (Dual Scale)

Selects output current for the application on various
materials and thicknesses. Current control is disabled
when Remote Control is used.

Current is adjustable for the application as follows:

• 50 to 150 amps for single power supply

• 100 to 300 amps for dual power supplies

OFF

ON

RUN

PURGE

SET

A-01502

AC

TEMP

GAS

PRES.

COOLANT

COND.

DC

PILOT

1

2

3

4

5

6

7

8

9

10

150

300

300

100

100

75

200

200

125

50

100

DUAL

DUAL

SINGLE

AMPS

150

150

250

250

Figure 4-3 Front Control Panel

4. AC Power Indicator

Green light indicates AC power is being supplied to
the system when the ON/OFF switch is in ON posi-
tion.

5. TEMP Indicator

Green light indicates proper operating temperature.
Red light indicates overheating. Unit must be allowed
to cool.

6. GAS Indicator

In RUN or SET position, yellow light indicates gas
pressure switches are satisfied when gas is flowing
to the torch. Light goes out in PURGE mode. RUN/
SET/PURGE switch must be in the RUN position for
proper cutting operation.

7. COOLANT PRES. (Coolant Pressure) Indicator

Yellow light indicates adequate coolant flow.

8. COOLANT COND. (Coolant Conductivity) Indica-

tor)

Yellow light indicates proper coolant conductivity.
Light out indicates excessive coolant conductivity (re-
sistivity less than 0.1 megaohms per centimeter). Re-
place coolant and de-ionizer cartridge.

9. DC Indicator

Yellow light indicates voltage is present at the power
supply output and cutting current is available.

10. PILOT Indicator

Yellow light indicates pilot arc contactor closure. Light
goes out when cutting arc is established and comes
back on if cutting arc is interrupted. Refer to Section
4.07-A and -B, Auto Restart Function.

C. Gauge Front Panel

Figure 4-4 Upper Gauge Panel

1. Secondary Pressure Control

Adjusts secondary gas pressure. Pull knob out and
turn clockwise to increase secondary pressure to de-
sired level.

2. Secondary Pressure Gauge

Displays secondary pressure from 0 - 100 psi (0 - 6.9
bar).

3. Secondary Mode Selector

Selects secondary mode to gas, oxygen (no second-
ary), or water. This mode selector is disabled when
using the Remote Gas Control Option (GC 3000).