08 primary power cable connections, 09 ground connections for mechanized applications – Tweco Merlin 6000 Master PS User Manual

Page 22

Advertising
background image

INSTALLATION PROCEDURES

3-4

Manual 0-2568

200, 208,

220, or 230

11

12

L3

13

15

14

6

7

L2

8

10

9

1

2

L1

3

5

4

380, 415,

or 460

11

12

L3

13

15

14

6

7

L2

8

10

9

1

2

L1

3

5

4

500, or 575

11

12

L3

13

15

14

6

7

L2

8

10

9

1

2

L1

3

5

4

Busbar Connections For Input Voltages

A-00904

Figure 3-5 Busbar Connections

If necessary, reposition the busbars to correspond to
the available line voltage.

3.08 Primary Power Cable

Connections

WARNING

Disconnect primary power at the source before con-
necting the primary power cable to the power sup-
ply.

The primary power cable must be supplied by the end
user and installed to the Power Supply assembly. Rec-
ommended cable sizes are specified in Appendix 1.

NOTE

Three-phase operation requires a 3-conductor cable
with ground.

1. Route the primary power cable through the strain

relief fitting in the rear panel of the Power Sup-
ply and tighten strain relief screws.

Input Voltage

Terminal Board

L1

L2

L3

Primary Power

Cable

Strain Relief

Fitting

Ground

Connection

Busbars

A-00893

Figure 3-6 Input Voltage Connections

2. Connect the electrical ground wire to the ground

lug on the base of the unit.

WARNING

The electrical ground wire must be connected to
the ground lug in the base of the unit for proper
grounding.

3. Connect the three line leads to the input voltage

terminal board per the following:

• Line 1 to terminal L1.

• Line 2 to terminal L2.

• Line 3 to terminal L3.

4. Tighten all nuts.

3.09 Ground Connections For

Mechanized Applications

NOTE

Refer to Appendix 3 for a block diagram of a typi-
cal mechanized system work and ground cable con-
nections.

A. Electromagnetic Interference (EMI)

Pilot arc initiation generates a certain amount of electro-
magnetic interference (EMI), commonly called RF noise.
This RF noise may interfere with other electronic equip-
ment such as CNC controllers, remote controls, height

Advertising